R24 / TECHNICAL DATA SHEET / EN PITANT UG (haftungsbeschränkt) · R24-TDS-EN · V1.3 · 26 November 2026 1 / 6 R24 Compliance Computer Paperless process recorder Universal inputs 8–24 Recording channels 48 Full scan¹ 100 ms Internal recording 64 GB nominal Supply¹ 100–240 V AC / 24 V DC ¹ Scan at 24 inputs and supply variant conditions are specified in sections 02 and 05. Assembled recorder 1 2 3 A FRONT / RIGHT 1 Panel bezel 2 Optically bonded touchscreen 3 Front USB Type-A 4 5 6 B REAR / EXAMPLE CONFIGURATION 4 Ventilation slots 5 Three plug-in input cards shown 6 Power and rear interfaces USB Type-A exports recorder files. Ethernet and isolated RS-485 carry live process values. Card quantity and type vary by order. Use the terminal schedule for the ordered unit. Section index 02 Measurement inputs 03 Outputs and plant interfaces 04 Recording, display and software 05 Panel installation and supply 06 Specify your R24
Page 2
R24 / TECHNICAL DATA SHEET / EN PITANT UG (haftungsbeschränkt) · R24-TDS-EN · V1.3 · 26 November 2026 2 / 6 Measurement inputs 8–24 universal inputs. Fitted input cards determine signal modes and measurement limits. At 24 inputs, the nominal full-scan interval is 100 ms with sequential card polling. Thermocouple conversion spans Type Range (°C) Type Range (°C) B 0 to 1,820 E −270 to 1,000 J −210 to 1,200 K −270 to 1,370 N −270 to 1,300 T −270 to 400 R −50 to 1,760 S −50 to 1,760 Type C: 0 to 2,310 °C software span. Specify the sensor reference curve and required measurement range when ordering. RTD conversion ranges Element Software span (°C) Software span (Ω) Pt100 −200 to 860 18.50–393.413 Pt1000 −200 to 860 185–3,934.13 jPt100 −100 to 500 59.57–284.02 Ni100 −100 to 420 74.25–248.66 Cu10 −100 to 260 5.12–19.11 2- or 3-wire input. Conversion spans describe software scaling. Measurement limits and permissible error depend on the input card and sensor. Electrical signals Signal Range or selection DC millivolt ±20 mV, ±100 mV DC voltage 0–1 V, ±1 V, 0–5 V, 1–5 V, 0–10 V, ±10 V, 0–20 V, ±20 V DC current 0–5 mA, 0–20 mA, 4–20 mA Frequency and binary Card-dependent. Specify level, frequency, duty cycle and quantity. Measurement conditions Parameter Reference value or condition Reference conditions 23 ± 2 °C, 55 ± 10% RH, nominal supply, ≥30 min warm-up Input impedance ≥10 MΩ for thermocouple and voltage ranges up to 1 V. ≥1 MΩ on higher voltage ranges. Current input burden ≤250 Ω at 20 mA Cold-junction compensation Base-metal thermocouples: ±0.5 °C at 23 ± 2 °C and ±0.7 °C over 0–50 °C RTD excitation and leads ≤1 mA for Pt100. 3-wire compensation for at least 10 Ω per matched lead. Filtering Per channel: off, 50/60 Hz rejection or smoothing Request the range-specific error limits for the selected card. Measurement inputs are for process signals only. Direct connection to mains is prohibited.
Page 3
R24 / TECHNICAL DATA SHEET / EN PITANT UG (haftungsbeschränkt) · R24-TDS-EN · V1.3 · 26 November 2026 3 / 6 Outputs and plant interfaces Output configuration Function Rating Conditions Current outputs Up to 8. 0–20 or 4–20 mA. Fitted output card External loop load 0–600 Ω at 20 mA ≥12 V compliance at minimum rated supply Output accuracy ±0.1% of 20 mA full scale (±20 μA) Reference conditions, selected output card Output timing 100 ms maximum update interval. ≤270 ms 10–90% step response. Specified load Relay contact form SPDT changeover, NO / COM / NC Fitted relay assembly Resistive switching Up to 5 A at 250 V AC or 30 V DC Specify load type and inrush. PID control Up to 8 simultaneous loops at 100 ms 8 fitted current outputs Specify the combined input, current output and relay population with the order. Physical interfaces Port Technical data Ethernet RJ45, 10/100BASE-TX, auto-negotiation Serial Isolated 2-wire RS-485, 4,800–115,200 baud, switchable 120 Ω termination USB USB Type-A host, USB 2.0 compatible. USB flash drive for recorder file export. Plant protocols Protocol Role Modbus TCP Server over Ethernet, up to four clients. Modbus RTU Responder on isolated RS-485. Secure Modbus TCP TLS protection with certificate-based authentication. OPC UA Read-only server for live process values. DNP3 and PROFINET Protocol add-ons available on request. Ethernet and RS-485 provide live process values for external logging. Export native recorder files via USB flash drive. Wire the recorder using the terminal schedule for the ordered configuration.
Page 4
R24 / TECHNICAL DATA SHEET / EN PITANT UG (haftungsbeschränkt) · R24-TDS-EN · V1.3 · 26 November 2026 4 / 6 Recording, display and software Acquisition and storage Function Technical data Acquisition Sequential polling. 100 ms nominal full-scan interval at 24 fitted inputs (10 updates/s per input). Recording Up to 48 shared Float32 channels for measured and calculated values. 100 ms recording interval (10 samples/s per recording channel). Internal recording capacity 64 GB nominal. Recorder file export Export native recorder files only to a USB flash drive via the USB Type-A host. Retention Depends on channel count, recording interval, archive overhead and usable capacity. Raw payload at 48 Float32 channels Per 24 h Per 365 days 100 ms recording interval 165.89 MB 60.55 GB 1 s (calculation only) 16.59 MB 6.05 GB These raw-sample figures use decimal units and exclude metadata, events, filesystem use and compression. Use available storage and archive overhead for your retention calculation. Display and batch operation Function Technical data Display Optically bonded 640 × 480 colour resistive touchscreen for glove or stylus use. Review Live and historical trends, grouped views and on-panel review of measured or calculated values. Eight configurable display groups. Batch capture Start runs manually or from a configured Modbus coil or recording channel. Up to eight equipment setups. Batch review Find runs by lot identifier, batch number or date. Review their trends and export data. Named local accounts identify operators who start or finish a manual run. Alarms and calculations Four thresholds per channel with hysteresis and sample confirmation. Build advanced alarm rules from calculated values. Engineering models 26 model types for gas, flow, production and thermal calculations. 16 totalisers track cumulative flow or consumption. Companion software Software Platform and function Archive Viewer Windows. Opens native RDBF archive files, reviews trends and gaps, exports data as CSV and produces CSV or PDF reports. Recorder Configurator Windows. Prepares and validates compatible settings files offline. For regulated applications, specify electronic records, signatures, audit and approval requirements.
Page 5
R24 / TECHNICAL DATA SHEET / EN PITANT UG (haftungsbeschränkt) · R24-TDS-EN · V1.3 · 26 November 2026 5 / 6 Panel installation and supply A 200.245 144.000 144.000 RIGHT SIDE FRONT REAR / EXAMPLE A: BOPLA NGS-NK side clamp · Bare enclosure dimensions in mm Mechanical and environmental data Parameter Value or installation condition CAD outline (W × H × D) 144 × 144 × 200.245 mm nominal. Allow additional space for connectors and cable bends. Mounting Indoor panel installation. Two BOPLA Uninorm NGS-NK screw clamps, order no. 37003000, one per side. Detail A shows the nominal fitted position. Panel interface Detail A uses a 3 mm reference panel. Use the cutout dimensions for the ordered configuration. Cabinet installation Install the recorder in a protective industrial cabinet. Operating conditions 0–50 °C at full population. 10–90% RH, non-condensing. Up to 2,000 m indoors. Storage −20 to +60 °C unpowered, non-condensing Installation category Pollution degree 2. AC supply overvoltage category II. Power supply Model Nominal supply Operating range AC 100–240 V AC, 50/60 Hz. Class I protective earth. 90–264 V AC, 47–63 Hz DC 24 V DC, ordered separately. 19.2–28.8 V DC Power budget: Allow 20 W for the recorder, including the USB load. Technical documents Download the signed EU Declaration of Conformity (AC and DC). Use the R24 enclosure drawing to plan cabinet space. Request the panel cutout and terminal schedule for the ordered configuration before machining or wiring.
Page 6
R24 / TECHNICAL DATA SHEET / EN PITANT UG (haftungsbeschränkt) · R24-TDS-EN · V1.3 · 26 November 2026 6 / 6 Specify your R24 Specify the input, output and supply configuration together. The quotation confirms the fitted hardware and ratings. Selection Information for the quote 1. Supply Choose 100–240 V AC or 24 V DC. Include actual site voltage, cabinet grounding and protection requirements. 2. Inputs Quantity by signal type, required ranges, RTD wiring and measurement error. Add any frequency or binary inputs. 3. Outputs Number of analogue outputs and PID loops, connected loop resistance, relay load type, AC or DC voltage, steady current and inrush. 4. Recording Number of values to record, recording interval, retention goal, batch triggers and required CSV or PDF reports. 5. Plant integration Modbus TCP, Modbus RTU, Secure Modbus TCP or OPC UA. Include DNP3 or PROFINET if required. 6. Installation Available panel depth and cutout, ambient conditions and required documents or application-specific approvals. Attach the I/O list or a cabinet drawing if available. 7. Order details Quantity, delivery country, target delivery date and your company/contact details. What the quote confirms Quote item Scope Configured instrument Supply version, fitted I/O, supported simultaneous population and protocol add-ons. Installation package Panel cutout, terminal schedule, configuration limits and documents for the delivery country. Commercial offer Unit quantity, included software or accessories, price and estimated lead time. Request a configuration quote Open an email with the configuration fields filled in as prompts. contact@pitant.de