Skip to content
R24 downloads

R24 enclosure drawing

PDF · EN · V1.2

Download PDF

Enclosure dimensions and views for cabinet planning.

Loading PDF preview…

Page 1

MECHANICAL DRAWING / 01
R24 assembled outline
Nominal enclosure dimensions with fitted BOPLA side clamps
A
200.245 144.00
144.00
RIGHT SIDE FRONT
TOP
PRINT CHECK
0 50 100 mm
DRAWING CONVENTIONS
ISO 5456-2 · First-angle orthographic projection
ISO 129-1 · Presentation of dimensions
Print at actual size for the stated drawing scale.
Panel interface
DETAIL A / FITTED SIDE CLAMP
2:1 at A3 · Dashed line marks rear face of reference panel
BOPLA NGS-NK (37003000) · one clamp per side · M4 × 70 screw.
Nominal geometry from BOPLA drawing · 3 mm reference panel.
CABINET PLANNING
Front bezel 144.00 × 144.00 mm
Middle housing, nominal 137.10 × 136.80 mm
Enclosure depth 200.245 mm
Installation documents
Allow additional space for connectors and cable bends.
Request the panel cutout and terminal schedule for the ordered unit
before machining the panel or wiring the recorder.
DRAWING
Assembled outline · R24-MECH V1.2
MODEL
R24
PROJECTION
First-angle orthographic
SCALE · UNITS
1:2 at A3 · mm
ISSUE DATE
26 November 2026
SHEET
1 / 2

Page 2

MECHANICAL DRAWING / 02
R24 assembled axonometrics
Fitted touchscreen, side clamps and representative rear connections
Front · right · top
Fitted touchscreen and front USB
Right NGS-NK side clamp
Rear · left · top
Example three-card configuration
Left NGS-NK side clamp
Read overall dimensions on sheet 1. ISO 5456-3 · Orthogonal isometric projection
DRAWING
Assembled isometrics · R24-MECH V1.2
MODEL
R24
PROJECTION
Orthogonal isometric
SCALE · UNITS
1:2 at A3 · mm
ISSUE DATE
26 November 2026
SHEET
2 / 2